Honeywell HW-AV-LTE-M-2: AlarmNet Cellular Fire Communicator Guide

Overview

The Honeywell HW-AV-LTE-M-2 is a cutting-edge AlarmNet fire communicator designed to replace traditional POTS lines with cellular connectivity. This fire alarm cellular communicator offers enhanced reliability and speed, making it a preferred choice for modern building safety systems. It's especially designed to integrate seamlessly with Silent Knight fire panels and provides a robust solution for businesses looking to upgrade their fire alarm communication infrastructure.

Technical Specifications

The Honeywell HW-AV-LTE-M-2 boasts a range of features that ensure high performance and compliance with industry standards. Below is a detailed technical specifications table:
Feature Specification
Cellular Network LTE / 4G
Protocols CLIP, IDNET, SLC
Wiring Class Class A/B
Certifications UL 268, FM Approved
Power Supply 12V DC
Dimensions 6.3" x 4.8" x 1.5"

Installation Requirements

Proper installation of the HW-AV-LTE-M-2 is crucial for optimal performance. Ensure that the communicator is installed in a location with strong cellular reception. It should be mounted in a secure, accessible location near the fire alarm control panel.
Pro Tip:

Always perform a signal strength test prior to finalizing the installation location to ensure reliable cellular connectivity.

Integration with Fire Alarm Systems

The HW-AV-LTE-M-2 integrates seamlessly with systems such as the Silent Knight SK-MINIMON Addressable Mini Monitor Module. Its ability to work with multiple protocols like CLIP and IDNET ensures compatibility with a wide range of fire alarm systems. This makes it an ideal choice for upgrading existing systems to a cellular-based communication model.

Programming and Configuration

Configuring the Honeywell HW-AV-LTE-M-2 requires accessing the AlarmNet 360 platform. Through this platform, technicians can manage and configure communication settings, ensuring that the device meets the specific needs of the building's fire safety system.
Pro Tip:

Regularly update the firmware via AlarmNet 360 to benefit from the latest security patches and feature enhancements.

Maintenance and Troubleshooting

Routine maintenance of the HW-AV-LTE-M-2 includes checking the device's status via AlarmNet 360 and ensuring it maintains a strong cellular signal. If issues arise, such as communication failure, verify the power supply and inspect for any physical damage. For challenging environments, consider pairing with compatible devices such as the Honeywell Silent Knight SK-HEAT-ROR-W Heat Rate of Rise Detector to enhance system reliability and performance.

FAQs

The HW-AV-LTE-M-2 supports LTE / 4G networks, ensuring reliable and fast communication.

Yes, its support for multiple protocols like CLIP and IDNET allows compatibility with various systems.

Perform a cellular signal strength test at the intended location to ensure strong and reliable connectivity.

Check the power supply, inspect for physical damage, and verify the cellular signal strength.

Find These Parts on FirePartsHub

Browse our verified inventory of Silent Knight components sourced from trusted eBay sellers: